15
Completing Initial
Configuration/Programming
After the last device is programmed, press ESC/NO.
The display shows END OF CONFIGURATION, then
changes to CLOSE THE PANEL.
STOP!
It is important that yourst mount all devices, then
secure the cover on the control panel. Failure to follow
this order of tasks will cause a tamper condition
from devices.
1. With the display showing CLOSE THE PANEL, do not
press YES.
2.
Mount all system devices at their permanent locations
3. Connect the supplied phone cord into the control panel
phone jack.
Note: The phone line can be run inside the wall
and through the back of the control panel, or it can
be run inside the wire cavity and out the end of the
control panel.
4. With the keypad display showing CLOSE THE PANEL,
secure the cover onto the control panel. The display
shows PANEL TAMPER ON OPEN = ALARM, then
OPERATION COMPLETED?
5.
Press YES. The display shows SYSTEM CHECK
IN PROGRESS.
The system performs a test of all programmed
devices. If all tampers are closed and battery
conditions in all devices are good, the display shows
INSTALLATION SUCCESSFUL, then changes to the
date, time, and current status (DISARMED LVL:3).
If there is no keypad activity for 40 seconds, the
display goes out to conserve battery power.